Applications for TEM
Imaging Plate Scanner Micron
For Transmission Electron Microscopy Applications - High resolution imaging plate scanner for all applications in transmission electron microscopy
Imaging Plates are nearly ideal electron detectors that give you highest quality digital images.
DITABIS Imaging Plate Technology enhances your results with all the benefits of digital imaging. Exploring the advantages of the Imaging Plate Technology, best results are obtained in resolution, linearity, sensitivity, dynamic range and DQE.
The almost ideal electron detector for a broad range of applications for
- Low dose cryo (biological or beam sensitive samples)
- High resolution TEM imaging for weak phase contrast samples
- Material science (material characterization)
- Diffraction pattern
High sensitivity and dynamic range
- Electron grey level conversion factor of five (approx. 10 times higher compared to negative film sensitivity)
- Linear range over 6 orders of magnitude
- Signal-to-noise ratio 1:10 (2 channels combined), 1:14 (with image corrections)
Additional advantages
- No wet chemistry needed
- Cost effective - reusable Imaging Plates, suitable for any TEM instruments
- Stand alone device
- Working at any microscopes accelerating voltages
- Second channel allows reflected laser light detection for advanced noise-correction.
Read more about New High-DQE Imaging Plate4 Scanner Using the Reflected Readout Laser Signar for Noice Correction
And see more: http://www.ditabis.de/micron_democlip_de.html
|
Scanner system specifications |
|
Readout pixels |
MicronVario |
Max. 6000 x 5000 at 15.0 μm (nominal pixel size) to
Max. 1800 x 1600 at 50.0 μm (nominal pixel size) |
|
Micron 25 |
Max. 3600 x 3200 at 25.0 μm (nominal pixel size) |
|
A/D-conversion |
True linear, 2 channels of 16 bit at different gains, 20 bit combined |
|
2 channels |
Channel 2 for additional signal detection, alternative reflected laser light detection |
|
Readout time |
2-3 min./5 frames |
|
Dynamic range |
Linear 6 orders of magnitude |
|
Resolution |
> 35% Modulation Transfer Function (MTF) at Nyquist frequency and > 50% at ½ Nyquist frequency (edge method, 120 KV) |
|
Power |
230 V - 50 Hz; 120 V - 60 Hz, 100W |
|
Dimensions (w / d / h) |
675 / 580 / 305 mm |
|
Weight |
60 kg |
|
|
|
Imaging Plates (reusable) |
|
Imaging Plate size |
81 x 100 mm |
|
Effective imaging area |
80 x 90 mm |
|
|
|
Data handling |
|
OS platforms |
Easy to use Windows 98 / NT / 2000 / XP |
|
Data format |
16 / 24 / 32 bit data format with comment and setting information in header |
|
Data conversion |
Data export to tif, pcx, gif, jpeg |
|
|
|
Software |
|
Scanning |
Full software control of all parameters, featuring application specific parameter sets |
|
Image viewer |
Quick preview, zoom and look-up-tables, data base functions |
|
Image processing |
Various filters and arithmetic functions, alignment, rotation, threshold |
|
Correction functions |
Background correction |
|
Analyse functions |
Points, lines and areas, 2D-FFT, 3D plot, peak measurement function |
|
|
|
|